SW-4040HF Sea Water Industrial RO Membrane 4040 Series High Flux
HIDTM Industrial Reverse Osmosis Membrane ranks the best brands in China among RO membrane industry. It has won the trust of thousands of families for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
HIDTM Sea Water Industrial RO Membranes – 4040 Series:
Being one of the earliest RO membranes manufacturers in China, HIDTM ranks the best brands among the Chinese RO membrane industry. Each RO membrane is made of HIDTM high rejection flat sheet and goes through most stringent manufacturing processes as well as in-house quality inspection & testing till delivery.
4040 series Sea Water RO membranes are widely used for filtration of tap water, underground water & brackish water; we well serve the industries including commercial drinking/food water treatment, electronics & chemical works, power plants, etc.
Sea Water RO Membranes Dimensions:
Model No. | A (inch/mm) | B (inch/mm) | C (inch/mm) |
SW-4040HF | 3.9/99.7 | 40/1016 | 0.75/19.1 |
Sea Water RO Membrane Model & Performance:
Model No. | Feed Spacer thickness (mil) |
Min. Salt Rejection (%) |
Stabilized Salt Rejection (%) |
Permeate Flow Rate (GPD) |
Test Pressure (psi) |
Test water TDS (ppm) |
Effective area ft² (m²) |
SW-4040HF | 28 | 99.6 | 99.7 | 1900 | 800 | 32800 | 90 (8.4) |
1. Permeate flow rate and salt rejection is based on testing conditions: 25℃, PH 7.5, 8% recovery.
2. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use, depending upon feedwater characteristics and operating conditions.
3. Active area guaranteed +/- 3%.
4. Permeate flow rate of single element varies by +/-15%.
5. Pressure drop of single element (max.): 15psi.
Sea Water RO Membranes Operating Limits:
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation* |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
SW-4040HF | 45℃ | 1200psi | 3-10 | 1NTU | 5 | <0.1ppm |
*for short term cleaning(30 min): 2-12
Sea Water RO Membranes General Information:
To ensure proper startup of RO water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock.
To follow the proper startup procedure (available with water treatment system guide book) also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.
Before initiating system startup procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.
Sea Water RO Membranes Operation Guidelines:
It is CRITICAL to avoid any abrupt pressure or cross-flow variations on the RO membrane elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. During startup, a gradual change from a standstill to operating state is recommended as follows:
• Feed pressure should be increased gradually over a 30-90 second time frame.
• Cross-flow velocity at set operating point should be achieved gradually over 15-30 seconds.
• Permeate obtained from the first hour of operation should be discarded.
Sea Water RO Membranes Important Information:
Keep RO membrane elements moist at all times after initial wetting.
If operating limits and guidelines given in this specification are not strictly followed, the limited warranty with the supplier will be null and void.
To prevent biological growth during prolonged system shutdowns, it is recommended that RO membrane elements be immersed in a storage solution.
The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
Avoid static permeate-side backpressure at all times.
HID RO Membranes are widely used in ultra-pure water, process pure water, cooling tower water, boiler water supply, pure water, throughout the electronics industry, optoelectronic industry, machinery manufacturing, fine chemical industry, medical pharmaceutical, food, and beverage industry, surface coating, and many other industries.